ECG Basics · Lesson 2 · From cell to trace

Why the heart beats by itself

Nodal cells have no stable resting potential. They slowly depolarise after every beat until they fire again, which is why the heart keeps a rhythm without any outside signal.

Three phases, not five

Sinoatrial (SA) and atrioventricular (AV) nodal cells start each cycle from a maximum diastolic potential of about −60 mV, much less negative than working muscle. From there:

What sets the rate

Rate depends on how long phase 4 takes. A steeper slope, a lower threshold or a less negative starting point reaches threshold sooner.

A hierarchy of backups

Several tissues can pace the heart. The fastest one wins: each of its beats resets the slower pacemakers before they reach threshold, and being driven faster than their own rate further depresses their automaticity (overdrive suppression).

PacemakerUsual rate when in chargeQRS when it takes over
SA node60–100 /minNarrow, preceded by upright P in II
AV junction40–60 /minUsually narrow, P absent, hidden or retrograde
Ventricle20–40 /minWide

When the SA node fails or impulses are blocked, the next pacemaker down produces an escape rhythm. When a lower pacemaker fires faster than its own escape range but slower than a tachycardia, it is an accelerated rhythm: accelerated junctional rhythm (about 60–100 /min) or AIVR (about 40–120 /min). It shows on the ECG when that rate is above the sinus rate, or when sinus slows below it.

The figure uses a published rabbit AV-node (N-cell) model, so its cycle (about 460 ms here) is faster than a resting human SA node. The phase shape is the teaching point, not the rate.
See it move in the live simulatorSinus arrest with escapeJunctional escapeAIVR