ECG Basics Part 2: Reading the paper Lesson 9 of 23
How to measure PR, QRS and QT
Updated
Every interval is a count of small boxes. At 25 mm/s one small box is 40 ms, so the real skill is finding the right start and end points and measuring more than one beat.
Small boxes to milliseconds
At the standard paper speed of 25 mm/s, one small (1 mm) box is 40 ms and one large (5 mm) box is 200 ms. Count the small boxes between the two points and multiply by 40. At 50 mm/s each small box is only 20 ms (see Lesson 7: The grid and calibration).
| Small boxes | Time at 25 mm/s | Where the number matters |
|---|---|---|
| 3 | 120 ms | Lower limit of a normal PR; a QRS this wide or wider is wide |
| 5 (one large box) | 200 ms | Upper limit of a normal PR |
| 10 | 400 ms | A QT of this length is normal or long depending on the heart rate |
| 11.5 | 460 ms | About the upper limit of a normal QTc in women (about 450 ms in men) |
| 12.5 | 500 ms | QTc above this carries a clearly higher risk of torsades |
PR interval
- Pick a lead where the start of the P wave is clear, usually II.
- Measure from the first deflection of the P wave to the first deflection of the QRS, whether that is a Q or an R wave.
- Count the small boxes: 3 to 5 boxes (120-200 ms) is normal.
- Measure several beats. A constant long PR is first-degree AV block; a PR that grows until a beat drops is Mobitz I; P waves that bear no fixed relation to the QRS, at a faster rate than the QRS, point to complete heart block (see Lesson 17: PR interval and AV block).
On this first-degree AV block strip the engine measures a PR of 278 ms: about 7 small boxes, well past the 5-box limit, and the same on every beat.
QRS duration
- Measure from the first deflection of the QRS to the J point, where the QRS ends and the ST segment begins.
- Use the lead where the QRS looks widest. Part of the QRS can run along the baseline in some leads, which makes it look narrower than it is.
- Under 3 small boxes (120 ms) is narrow. 3 boxes or more is wide: bundle branch block, a ventricular rhythm, pacing, pre-excitation, or a drug or electrolyte effect (see Lesson 18: Narrow vs wide QRS: bundle branch block).
On this right bundle branch block strip the engine measures a QRS of 151 ms, almost 4 small boxes: wide, with the rSR′ shape of RBBB in V1.
QT interval and QTc
- Choose the lead with the longest clear T wave, often II or V5.
- Measure from the start of the QRS to the end of the T wave. Where the end is gradual, use the tangent method: draw a line along the steepest part of the T wave's final limb (the downslope of an upright T, the upslope of an inverted T); the end of the T wave is where that line crosses the baseline.
- Leave out a separate U wave. If the U wave merges with the T wave, use the tangent method on the T wave or measure in a lead where the U wave is small (often aVR or aVL); if no T-wave end can be found, report it as a QTU interval rather than a QT.
- Correct for heart rate. Bazett's formula divides the QT by the square root of the RR interval in seconds; Fridericia's uses the cube root, and over-corrects less at fast rates and under-corrects less at slow rates.
On this long QT strip the engine measures a QT of 509 ms at a heart rate of 65/min (RR 923 ms). Bazett: 509 ÷ √0.923 ≈ 530 ms, above 500 ms. A worked example at a normal rate: a QT of 400 ms at 75/min (RR 0.8 s) gives a Bazett QTc of 400 ÷ √0.8 ≈ 447 ms.
When the rhythm or the QRS makes it harder
- Irregular rhythm, such as atrial fibrillation: the PR does not exist and the QT changes with every RR interval. Measure several beats and average them, rather than one beat after a long or a short pause.
- Wide QRS (bundle branch block, pacing): the wide QRS itself lengthens the QT. Compare with earlier ECGs, or look at the JT interval (QT minus QRS duration), before calling the repolarization long.
- Fast rates: Bazett over-corrects, so a QTc at a fast rate can look long when it is not; Fridericia is less affected.
Common errors
- Starting the PR at the peak of the P wave instead of its first deflection.
- Measuring the QRS in a lead where its start lies on the baseline, which makes it look narrow.
- Counting a separate U wave as part of the QT.
- Reading one beat of an irregular rhythm as if it were typical.
- Not checking the paper speed before counting boxes.
Key points
- One small box is 40 ms at 25 mm/s: count boxes, then multiply.
- PR and QRS start at the first deflection; QT ends where the T wave returns to baseline, found by the tangent method when it is gradual.
- Measure more than one beat, use the widest QRS and the longest clear QT, and always correct QT for rate.
Read the rhythm pages1st-degree AV blockRight bundle branch blockProlonged QT interval
References
- Kligfield P, et al. Recommendations for the standardization and interpretation of the electrocardiogram, Part I: the electrocardiogram and its technology. Circulation 2007;115:1306-1324. doi:10.1161/CIRCULATIONAHA.106.180200
- Surawicz B, et al. Recommendations for the standardization and interpretation of the electrocardiogram, Part III: intraventricular conduction disturbances. J Am Coll Cardiol 2009;53:976-981. doi:10.1016/j.jacc.2008.12.013
- Rautaharju PM, et al. Recommendations for the standardization and interpretation of the electrocardiogram, Part IV: the ST segment, T and U waves, and the QT interval. J Am Coll Cardiol 2009;53:982-991. doi:10.1016/j.jacc.2008.12.014
- Postema PG, De Jong JS, Van der Bilt IA, Wilde AAM. Accurate electrocardiographic assessment of the QT interval: teach the tangent. Heart Rhythm 2008;5(7):1015-1018. The tangent method for the end of the T wave. doi:10.1016/j.hrthm.2008.03.037
SIMULATED · NOT FOR DIAGNOSIS · TracingsMD ECG Basics
Saving is off. Marks last for this page only.
Save progress on this device?