ECG rhythms Side-by-side comparisons
Sinus arrhythmia vs PACs
Updated
Both make a sinus rhythm irregular with narrow QRS complexes. In respiratory sinus arrhythmia the sinus rate rises and falls smoothly with breathing and every P wave looks the same. A premature atrial complex is a single beat that comes suddenly early, with its own early P wave, followed by a pause.
The strips side by side
Respiratory sinus arrhythmia
Premature atrial complexes
Computed by the TracingsMD heart model: simulated for education, not a patient recording and not for diagnosis.
Here because of a watch alert or a symptom? This site cannot tell what your own heart is doing. Talk to a doctor or nurse about it, and call emergency services for chest pain, fainting or trouble breathing.
Differences at a glance
Scroll the table sideways to read all columns.
| Feature | Respiratory sinus arrhythmia | Premature atrial complexes |
|---|---|---|
| Pattern | A gradual, repeating change with breathing | A sudden early beat that breaks an otherwise regular rhythm |
| P waves | The same shape before every QRS | The early beat has its own early P wave, which may look different |
| PR | Constant (about 160 ms here) | Can be a little longer in the early beat (about 170 ms here, 160 ms in the sinus beats) |
| After the irregular beat | No pause; the next cycle continues the smooth change | A pause, usually non-compensatory |
| Who has it | Common and normal, especially in the young; more marked with slow, deep breathing | Any age, more often with age; triggers such as caffeine, alcohol or stress |
How to tell them apart
- March out the P waves with calipers: in sinus arrhythmia each PP interval differs only a little from the one before it; before a PAC the PP interval is suddenly short.
- Compare the P-wave shapes: one shape throughout favors sinus arrhythmia.
- Watch the breathing, or ask the person to hold a breath: sinus arrhythmia becomes regular, PACs do not.
- Several P-wave shapes with a changing PR point to a wandering atrial pacemaker or, above 100/min, multifocal atrial tachycardia.
Why it matters
- Respiratory sinus arrhythmia is normal and needs no treatment.
- Isolated PACs are usually benign; frequent ones are worth noting because of their link with later atrial fibrillation.
Each rhythm on its own page
References
- Sandau KE, Funk M, Auerbach A, et al. Update to practice standards for electrocardiographic monitoring in hospital settings. Circulation 2017;136(19):e273-e344.
- Page RL, Joglar JA, Caldwell MA, et al. 2015 ACC/AHA/HRS guideline for the management of adult patients with supraventricular tachycardia. Circulation 2016;133(14):e506-e574.