ECG rhythms Side-by-side comparisons

Fine VF vs asystole

Updated

In cardiac arrest both can look like a nearly flat line. Fine ventricular fibrillation is low-amplitude chaotic electrical activity and is shockable. Asystole is the absence of ventricular electrical activity and is not. A flat line can also be a false asystole from a loose lead, a low gain setting, or a single lead that happens to sit at right angles to the fibrillation waves, so a flat line is checked before it is called asystole.

The strips side by side

Fine ventricular fibrillation

Fine ventricular fibrillation ECG strip, lead II, 10 seconds at 25 mm/s and 10 mm/mV
Lead II, 10 seconds (25 mm/s, 10 mm/mV). Irregular low-amplitude waves (under about 0.5 mV peak to peak here) with no QRS complexes and no flat stretches. Watch fine ventricular fibrillation on its live strip.

Asystole

Asystole ECG strip, lead II, 10 seconds at 25 mm/s and 10 mm/mV
Lead II, 10 seconds (25 mm/s, 10 mm/mV). A flat line apart from slow baseline drift: no QRS complexes and no fibrillation waves. Watch asystole on its live strip.

Computed by the TracingsMD heart model: simulated for education, not a patient recording and not for diagnosis.

Here because of a watch alert or a symptom? This site cannot tell what your own heart is doing. Talk to a doctor or nurse about it, and call emergency services for chest pain, fainting or trouble breathing.

Differences at a glance

Scroll the table sideways to read all columns.

FeatureFine ventricular fibrillationAsystole
BaselineIrregular, chaotic small wavesFlat, apart from slow drift
QRS complexesNoneNone
Other leadsFibrillation waves show in other leads tooFlat in every lead
P wavesNoneNone; P waves without any QRS are P-wave asystole (ventricular standstill), also not shockable
ShockableYesNo

How to tell them apart

  1. Check that the leads are attached and that the monitor shows the leads you think it shows.
  2. Increase the gain and look at a second lead: fine VF shows waves in another lead, true asystole stays flat.
  3. Look for P waves without QRS complexes: that is P-wave asystole, not VF.
  4. Keep the pause in chest compressions for the rhythm check as short as possible.