ECG rhythms Atrial and supraventricular
Wandering atrial pacemaker ECG
Also called WAP.
Updated
Wandering atrial pacemaker. An irregular narrow rhythm under 100/min, a P wave before every QRS, P waves of three or more shapes and a changing PR.
A 30-second recording of the heart model, played in real time. Run live runs the heart model itself with this rhythm.
Computed by the TracingsMD heart model: simulated for education, not a patient recording and not for diagnosis.
Here because of a watch alert or a symptom? This site cannot tell what your own heart is doing. Talk to a doctor or nurse about it, and call emergency services for chest pain, fainting or trouble breathing.
Measured on this recording
| Ventricular rate (HR) | 69-86/min |
|---|---|
| PR | 138-221 ms, changing beat to beat |
| QRS | 84 ms |
| QT | 345 ms |
| QTc (Bazett) | 399 ms |
| QTc (Fridericia) | 380 ms |
What it is
The pacemaker shifts between the sinus node, other atrial sites and sometimes the AV junction, so the P-wave shape and the PR interval change from beat to beat, with at least three P-wave shapes, at a rate under 100/min. The RR intervals are mildly irregular. It is the slower relative of multifocal atrial tachycardia.
How to read this strip
| Rate | About 78/min on average (under 100/min). |
|---|---|
| Rhythm | Irregular. |
| P waves | Present before every QRS, with at least three different shapes over the strip. |
| PR | Varies with the P-wave focus. |
| QRS | Narrow. |
| QT | Normal. |
Causes
- High vagal tone: sleep, athletes, healthy young people.
- Digoxin and other drugs that slow the sinus node.
- Chronic lung disease (with a faster rate it becomes multifocal atrial tachycardia).
- Sinus node dysfunction in older people.
What to consider
- Usually benign and needs no treatment.
- Look at a long strip: the P-wave changes are easy to miss in a few beats.
- If the rate rises above 100/min the rhythm is multifocal atrial tachycardia: look for lung disease, hypoxia and low potassium or magnesium.
- With symptomatic slow rates or pauses, consider sinus node dysfunction and review drugs.
Key point
A wandering atrial pacemaker has the same three or more P-wave shapes as multifocal atrial tachycardia, at a rate under 100/min, and is usually benign.
Not to be confused with
- Multifocal atrial tachycardia. The same changing P waves at a rate above 100/min.
- Respiratory sinus arrhythmia. The rate changes with breathing, but every P wave has the same sinus shape and the PR stays constant.
- Sinus rhythm with premature atrial complexes. A regular sinus rhythm interrupted by early beats with a different P wave, not a gradual change of P-wave shape.
- Atrial fibrillation. No distinct P waves before the QRS complexes.
Side by side: Sinus arrhythmia vs PACs
Practice with this rhythm
References
- Goldberger's Clinical Electrocardiography: A Simplified Approach, 10th edition (Elsevier, 2023)
- Page RL, Joglar JA, Caldwell MA, et al. 2015 ACC/AHA/HRS guideline for the management of adult patients with supraventricular tachycardia. Circulation 2016;133(14):e506-e574.