ECG rhythms Side-by-side comparisons

Sinus arrest vs sinus exit block

Updated

Both leave a pause in sinus rhythm with no P wave in it. The difference is timing. In sinus exit block the sinus node keeps firing on time but an impulse fails to leave it, so the pause is an exact multiple of the PP interval. In sinus arrest the node itself stops, so the pause has no fixed relation to the PP interval and often ends with an escape beat.

The strips side by side

Sinus arrest

Sinus arrest ECG strip, lead II, 10 seconds at 25 mm/s and 10 mm/mV
Lead II, 10 seconds (25 mm/s, 10 mm/mV). Sinus P waves stop for about 2.1 s in this 10-second strip (longer pauses come later in the recording), against a PP interval of about 0.8 s (not a multiple). A narrow escape beat with no P wave (junctional) fills each pause about 1.5 s after the last sinus beat. Watch sinus arrest on its live strip.

Sinus exit block

Sinus exit block ECG strip, lead II, 10 seconds at 25 mm/s and 10 mm/mV
Lead II, 10 seconds (25 mm/s, 10 mm/mV). Pauses of about 1.6 s, exactly twice the PP interval of about 0.8 s, ended by the next sinus P wave on time. Watch sinus exit block on its live strip.

Computed by the TracingsMD heart model: simulated for education, not a patient recording and not for diagnosis.

Here because of a watch alert or a symptom? This site cannot tell what your own heart is doing. Talk to a doctor or nurse about it, and call emergency services for chest pain, fainting or trouble breathing.

Differences at a glance

Scroll the table sideways to read all columns.

FeatureSinus arrestSinus exit block
Pause length (P to P)Not a multiple of the PP interval (about 2.1 s here, PP 0.8 s)An exact multiple of the PP interval (about 1.6 s here, twice the PP)
What failsThe sinus node stops firingThe sinus node fires, but the impulse does not leave the node
Beat that fills the pauseOften an escape beat (junctional here: narrow, no P wave)The next sinus P wave, on time
P wavesNormal sinus P waves between pauses; none in the pauseNormal sinus P waves; none in the pause
PR and QRSNormal PR in the sinus beats; narrow QRSNormal, constant PR; narrow QRS

How to tell them apart

  1. Measure the PP interval in a run of regular sinus beats, with calipers or by counting small boxes.
  2. Measure the pause from the last P wave before it to the next P wave.
  3. If the pause equals two (or three) PP intervals, the sinus node kept time: sinus exit block. If it does not, the node stopped: sinus arrest.
  4. Look at the beat that fills the pause: an escape beat with no P wave before it favors sinus arrest.
  5. Before calling either, check the T wave before the pause for a hidden early P wave (a blocked premature atrial complex), and look for a P wave that arrives on time without a QRS (AV block).

Why it matters

Each rhythm on its own page

References

  1. Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay. Circulation 2019;140(8):e382-e482.
  2. Sandau KE, Funk M, Auerbach A, et al. Update to practice standards for electrocardiographic monitoring in hospital settings. Circulation 2017;136(19):e273-e344.