ECG rhythms Side-by-side comparisons
Sinus arrest vs sinus exit block
Updated
Both leave a pause in sinus rhythm with no P wave in it. The difference is timing. In sinus exit block the sinus node keeps firing on time but an impulse fails to leave it, so the pause is an exact multiple of the PP interval. In sinus arrest the node itself stops, so the pause has no fixed relation to the PP interval and often ends with an escape beat.
The strips side by side
Sinus arrest
Sinus exit block
Computed by the TracingsMD heart model: simulated for education, not a patient recording and not for diagnosis.
Here because of a watch alert or a symptom? This site cannot tell what your own heart is doing. Talk to a doctor or nurse about it, and call emergency services for chest pain, fainting or trouble breathing.
Differences at a glance
Scroll the table sideways to read all columns.
| Feature | Sinus arrest | Sinus exit block |
|---|---|---|
| Pause length (P to P) | Not a multiple of the PP interval (about 2.1 s here, PP 0.8 s) | An exact multiple of the PP interval (about 1.6 s here, twice the PP) |
| What fails | The sinus node stops firing | The sinus node fires, but the impulse does not leave the node |
| Beat that fills the pause | Often an escape beat (junctional here: narrow, no P wave) | The next sinus P wave, on time |
| P waves | Normal sinus P waves between pauses; none in the pause | Normal sinus P waves; none in the pause |
| PR and QRS | Normal PR in the sinus beats; narrow QRS | Normal, constant PR; narrow QRS |
How to tell them apart
- Measure the PP interval in a run of regular sinus beats, with calipers or by counting small boxes.
- Measure the pause from the last P wave before it to the next P wave.
- If the pause equals two (or three) PP intervals, the sinus node kept time: sinus exit block. If it does not, the node stopped: sinus arrest.
- Look at the beat that fills the pause: an escape beat with no P wave before it favors sinus arrest.
- Before calling either, check the T wave before the pause for a hidden early P wave (a blocked premature atrial complex), and look for a P wave that arrives on time without a QRS (AV block).
Why it matters
- Both are forms of sinus node dysfunction and are judged the same way: by symptoms, drugs and reversible causes, not by the name of the pause.
- When the sinus rate varies naturally (sinus arrhythmia), the PP interval is hard to pin down and exit block cannot always be proven; the label matters less than whether the pauses cause symptoms.
- The multiple rule applies to type II sinus exit block, shown here. In the rarer type I (Wenckebach) form the PP intervals shorten before a pause that is less than two PP intervals, so it can be mistaken for sinus arrest.
Each rhythm on its own page
References
- Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay. Circulation 2019;140(8):e382-e482.
- Sandau KE, Funk M, Auerbach A, et al. Update to practice standards for electrocardiographic monitoring in hospital settings. Circulation 2017;136(19):e273-e344.