ECG rhythms Side-by-side comparisons

Mobitz I vs Mobitz II AV block

Updated

Both are second-degree AV block: some P waves are not followed by a QRS. In Mobitz I (Wenckebach) the PR lengthens beat by beat until a P wave is not conducted, and the block is usually in the AV node. In Mobitz II the PR stays the same before and after the dropped beat, and the block is usually below the AV node, where it can progress to complete heart block. With 2:1 conduction there are never two conducted beats in a row, so the PR pattern cannot show which type it is.

The strips side by side

Mobitz I (Wenckebach)

Mobitz I (Wenckebach) ECG strip, lead II, 10 seconds at 25 mm/s and 10 mm/mV
Lead II, 10 seconds (25 mm/s, 10 mm/mV). PR 160, then about 240, then about 280 ms, then a P wave without a QRS; the cycle repeats (group beating). Watch Mobitz I (Wenckebach) on its live strip.

Mobitz II

Mobitz II ECG strip, lead II, 10 seconds at 25 mm/s and 10 mm/mV
Lead II, 10 seconds (25 mm/s, 10 mm/mV). PR about 160 ms on every conducted beat, the same before and after each P wave that is not conducted. Watch Mobitz II on its live strip.

2:1 AV block

2:1 AV block ECG strip, lead II, 10 seconds at 25 mm/s and 10 mm/mV
Lead II, 10 seconds (25 mm/s, 10 mm/mV). Every second P wave is not conducted; the PR of the conducted beats is constant, so the type cannot be told from this strip. Watch 2:1 AV block on its live strip.

Computed by the TracingsMD heart model: simulated for education, not a patient recording and not for diagnosis.

Here because of a watch alert or a symptom? This site cannot tell what your own heart is doing. Talk to a doctor or nurse about it, and call emergency services for chest pain, fainting or trouble breathing.

Differences at a glance

Scroll the table sideways to read all columns.

FeatureMobitz I (Wenckebach)Mobitz II2:1 AV block
PR before the dropped beatLengthens progressively (160 to about 280 ms here)Constant (about 160 ms here)Constant, but never two conducted beats in a row
PR after the dropped beatShortest of the groupThe same as before itNot informative
RhythmGroup beating; irregularIrregular because of dropped beatsRegular
Usual level of blockAV nodeBelow the AV node (His-Purkinje system)Either
QRSUsually narrowOften wide (bundle branch block); narrow hereNarrow here; a wide QRS favors block below the AV node
RiskUsually benignCan progress suddenly to complete heart blockDepends on the level of block

How to tell them apart

  1. Find the dropped beat: a P wave that arrives on time with no QRS after it.
  2. Compare the PR just before the dropped beat with the PR just after it: longer before and shorter after is Mobitz I; the same is Mobitz II.
  3. Check for group beating: Wenckebach clusters beats into groups separated by pauses.
  4. If the strip only ever shows 2:1 conduction, call it 2:1 AV block; a longer strip, another rate or the QRS width can help place it.
  5. Make sure the dropped P wave is on time: an early P wave that is not conducted is a blocked premature atrial complex, not AV block.

Why it matters

Each rhythm on its own page

References

  1. Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay. Circulation 2019;140(8):e382-e482.
  2. Sandau KE, Funk M, Auerbach A, et al. Update to practice standards for electrocardiographic monitoring in hospital settings. Circulation 2017;136(19):e273-e344.