ECG Practice

ECG Interpretation

Read a rhythm strip or a 12-lead ECG, choose the rhythm (and for some cases the next step), then check. Some cases then ask you to find the key wave on the tracing. The answer shows the tracing annotated beat by beat, a systematic read and the guideline behind it.

Tracings are computed by the TracingsMD physiology engine: simulated, not patient recordings, and not for diagnosis. This is educational practice, not a clinical examination.

Interpretation · 27 cases

Level
Length
Focus

New to ECG reading? Start at Beginner, and use Theory or the Basics lessons when a term is unfamiliar. Cases come in random order, and the same rhythm can return as a different engine recording: the rate and timing change, so you read the ECG, not a remembered picture. Not sure? Use “Show answer” to see the explanation without scoring.

Your practice records

Saving is off. Practice records last for this page only.

One setting covers Theory and Interpretation.

How records are kept

A case counts as missed if any of its answers was wrong. Each case keeps its latest result and, after a miss, when to review it: the next day, then 3 and 6 days after each correct review, until three reviews in a row are correct. Reviews and retries mix in one look-alike rhythm for each missed case, picked from that case’s wrong answers; which answer you chose is not saved. Answers shown without scoring are not saved. Tracing tasks count on this page only and are never saved; measurements are not scored or saved. Clearing removes both sets' records on this device. Turning saving off deletes device records and keeps this page's temporary records until you leave.

How these cases are made

Every tracing is recorded output of the TracingsMD physiology engine (Lead II and other leads at 500 samples per second, 25 mm/s, 10 mm/mV), with no patient recordings and no generative AI. Annotations are placed from the engine's own beat events: where it started each P wave and QRS complex, which P waves it did not conduct, and the intervals it measured. Measurements are model values, not clinical measurements. QRS width is the whole ventricular activation, from the earliest start to the latest end across all leads, as QRS duration is measured on a 12-lead ECG; in a single lead the last part can be nearly flat, so a wide QRS can look 20-35 ms narrower there. QT is taken from one beat of the underlying rhythm with a typical RR interval (never an early beat or the beat after a pause), and the table uses the same beat as the QT bracket. P waves that fall inside a QRS complex are outlined in gray: the engine times them, but they cannot be seen.

A “Find it on the tracing” task is judged by the wave your mark lands on, using the same engine events as the annotations. The first and last 0.35 s of the strip are not judged, nor (when you look for a P wave) any QRS-T, because a wave there can be cut off or hidden. “Measure it yourself” (PR or QT on one magnified beat) is never scored: it shows your value beside the engine’s, because careful readers measuring the same beat by hand often differ by 10-30 ms.

Each case has one or more recordings of the same rhythm at different rates. Answers follow the references listed with each case; management answers follow the AHA 2025 adult advanced life support algorithms, as on the ACLS Scenarios page. Patterns are teaching examples; real tracings vary more, and a single lead cannot resolve every rhythm.

Abbreviations

PR
PR interval: start of the P wave to the start of the QRS
QRS
QRS complex: ventricular depolarization
QTc
QT interval corrected for heart rate
AV
atrioventricular
SA
sinoatrial
bpm
beats per minute
AF
atrial fibrillation
SVT
supraventricular tachycardia
VT
ventricular tachycardia
VF
ventricular fibrillation
PVC
premature ventricular complex
PAC
premature atrial complex
LBBB
left bundle branch block
RBBB
right bundle branch block
STEMI
ST-elevation myocardial infarction
WPW
Wolff-Parkinson-White
ROSC
return of spontaneous circulation
PEA
pulseless electrical activity
EtCO₂
end-tidal carbon dioxide
MAP
mean arterial pressure
IO
intraosseous
IV
intravenous
CPR
cardiopulmonary resuscitation
AED
automated external defibrillator
pVT
pulseless ventricular tachycardia

Reading or printing instead? Every item with its answer is on one page: ECG practice strips with answers.

References

Each explanation links its own source; together, the practice sets follow these.

  1. Kligfield P, Gettes LS, Bailey JJ, et al. Recommendations for the standardization and interpretation of the electrocardiogram, Part I: the electrocardiogram and its technology. Circulation 2007;115(10):1306-1324. doi:10.1161/CIRCULATIONAHA.106.180200
  2. Surawicz B, Childers R, Deal BJ, et al. Recommendations for the standardization and interpretation of the electrocardiogram, Part III: intraventricular conduction disturbances. J Am Coll Cardiol 2009;53(11):976-981. doi:10.1016/j.jacc.2008.12.013
  3. Rautaharju PM, Surawicz B, Gettes LS, et al. Recommendations for the standardization and interpretation of the electrocardiogram, Part IV: the ST segment, T and U waves, and the QT interval. J Am Coll Cardiol 2009;53(11):982-991. doi:10.1016/j.jacc.2008.12.014
  4. Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay. Circulation 2019;140(8):e382-e482. doi:10.1161/CIR.0000000000000628
  5. Page RL, Joglar JA, Caldwell MA, et al. 2015 ACC/AHA/HRS guideline for the management of adult patients with supraventricular tachycardia. Circulation 2016;133(14):e506-e574. doi:10.1161/CIR.0000000000000311
  6. Brugada J, Katritsis DG, Arbelo E, et al. 2019 ESC guidelines for the management of patients with supraventricular tachycardia. Eur Heart J 2020;41(5):655-720. doi:10.1093/eurheartj/ehz467
  7. Joglar JA, Chung MK, Armbruster AL, et al. 2023 ACC/AHA/ACCP/HRS guideline for the diagnosis and management of atrial fibrillation. Circulation 2024;149(1):e1-e156. doi:10.1161/CIR.0000000000001193
  8. Drew BJ, Ackerman MJ, Funk M, et al. Prevention of torsade de pointes in hospital settings. Circulation 2010;121(8):1047-1060. doi:10.1161/CIRCULATIONAHA.109.192704
  9. Sandau KE, Funk M, Auerbach A, et al. Update to practice standards for electrocardiographic monitoring in hospital settings. Circulation 2017;136(19):e273-e344. doi:10.1161/CIR.0000000000000527
  10. Thygesen K, Alpert JS, Jaffe AS, et al. Fourth universal definition of myocardial infarction (2018). Circulation 2018;138(20):e618-e651. doi:10.1161/CIR.0000000000000617
  11. Rao SV, O'Donoghue ML, Ruel M, et al. 2025 ACC/AHA/ACEP/NAEMSP/SCAI guideline for the management of patients with acute coronary syndromes. Circulation 2025;151(13):e771-e862. doi:10.1161/CIR.0000000000001309
  12. Wigginton JG, Agarwal S, Bartos JA, et al. Part 9: adult advanced life support: 2025 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2025;152(16 Suppl 2):S538-S577. doi:10.1161/CIR.0000000000001376
  13. American Heart Association. Adult tachyarrhythmia with a pulse algorithm, 2025. Open source
  14. American Heart Association. Adult cardiac arrest algorithm, 2025. Open source
  15. Batchvarov VN, Malik M, Camm AJ. Incorrect electrode cable connection during electrocardiographic recording. Europace 2007;9(11):1081-1090. doi:10.1093/europace/eum198